The oxidation process begins at low temperatures where CO emissions start to oxidize to CO2. As the exhaust temperature increases to 580 oF and above, the oxidation process rapidly accelerates dramatically reducing diesel particulate matter (DPM), hydrocarbon emissions (HC) and odors. Following a short break-in period, particulate matter reductions between 90-95% are commonly achieved. To maintain filter self-regeneration, the exhaust temperature must be maintained at a minimum temperature of approximately 580 oF (300 oC) for a minimum of 30% of the duty cycle. As soon as exhaust gas passes through the particulate filter, it begins to capture soot particles. The particles remain trapped on the wall-flow filter's surfaces until the exhaust temperature reaches the minimum self-regeneration temperature (580 oF) when they begin to actively interact with the catalyst oxidizing the trapped particles that consist of hard carbonaceous material, soluble organic fraction (SOF) and other combustion by-products. The trapped materials are oxidized and converted to harmless, gaseous carbon dioxide (CO2) and water vapor (H2O). As long as the operating temperature remains above of the minimum regeneration temperature, the trapped soot particles undergo the oxidation process and the filter remains in a regeneration mode. The filter pressure drop will depend upon the amount of trapped particles. The longer the filter remains in the regeneration mode, the lower the unit pressure drop. The preferred diesel fuel grade ultra-low sulfur diesel (ULSD) containing 15 ppm sulfur or less. This grade fuel will allow regeneration to occur at the lowest possible temperature with minimum required duty-cycle period. Should fuel containing higher levels of sulfur be utilized, the required minimum operating temperature will increase and operation at 700 oF and above is recommended for the minimum 30% of the duty cycle. Because our washcoat and catalyst formulations are sulfur tolerant, operating at the higher sulfur level will not damage the catalyst coating or the ceramic (cordierite) filter element.
diesel catalyst diesel exhaust purifiers diesel soot filters diesel particulate filters diesel soot traps voc catalyst oxidation catalyst diesel catalytic
converter catalytic convertor diesel soot trap flow-through catalyst three-way catalyst
Click the icon below to send an E-mail message and request a quotation or obtain more information.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||