Repairing Aluminum Wiring US Consumer Product Safety Commission Publication #516
NOTE: This document has been scanned verbatim from the CPSC document and is straight ASCII text except where we have inserted the graphics images.
REPAIRING ALUMINUM WIRING
CPSC #516
U.S. Consumer Product
Safety Commission
Washington DC 20207
ALUMINUM WIRING
° On April, 28,1974, two persons died in a home fire in Hampton
Bays, New York. Fire officials determined that the fire was caused by a
faulty aluminum wire connection at an outlet.
° Since that tragic accident, the U.S. Consumer Product Safety
Commission staff and other government officials have investigated
numerous complaints from homeowners throughout the nation who
have had trouble with small gauge aluminum branch circuit wiring. The
Commission has also had research conducted that shows that homes
wired with aluminum wire manufactured before 1972 ("old technology"
aluminum wire) are 55 times more likely to have one or more
connections reach "Fire Hazard Conditions" than is a home wired
with copper.
° The hazard investigated by the Commission staff occurs at
connections to old technology aluminum wire, such as at outlets or
switches or at major appliances such as dishwashers, furnaces, etc.
Corrosion of the metals in the connection, particularly the aluminum
wire itself, causes increased resistance to the flow of electric current
and that resistance causes overheating.
° Homes built before 1965 are unlikely to have aluminum branch
circuit wiring. Homes built, rooms added, and circuits rewired or added
between 1965 and 1973 may contain aluminum wiring.
° In 1972, manufacturers modified both aluminum wire and switches
and outlets to improve the performance of aluminum wired
connections. Sale of the old style wire, switches and outlets still on
dealers' shelves however, continued after 1972.
TROUBLE SIGNS
° Signs of trouble in aluminum wire systems include warm-to-the-
touch face plates on outlets or switches, flickering lights, circuits that
don't work, or the smell of burning plastic at outlets or switches.
Unfortunately, not all failing aluminum wired connections provide such
easily detected warning signs; aluminum wired connections have
been reported to fail without any prior indications or problems.
1 (footnote) The survey conducted by the Franklin Research Institute defined
"Fire Hazard Conditions" to occur when receptacle coverptate mounting screws
reached 149~C (3O0~F), or sparks were emitted from the receptacle, or materials
around the receptacle were charred.
WHAT THE HOMEOWNER CAN DO
° If you have noticed any of the trouble signs, have a qualified
electrician determine whether the problem is caused by deteriorating
connections to aluminum wiring. DO NOT TRY TO DO IT YOURSELF.
You could be electrocuted or you could make the connections worse
by disturbing them. If you are not certain whether your home has
aluminum branch circuit wiring, you may be able to tell by looking at the
If you do have aluminum branch circuit wiring, the Commission
suggests that you have a qualified electrician check the system for
impending trouble. Remember, you may not have noticed any of the
warning signs, but research shows that trouble may develop over time
and an electrician may spot potential problems before you notice
them.